In short
- DC-coupled batteries connect to the solar panels' direct current, before the inverter. AC-coupled batteries connect on the mains side, after the inverter.
- AC coupling is usually the easier way to add a battery to panels and an inverter you already have.
- Your existing panels, inverter or microinverter, and the battery's own limits all decide what fits.
- A fixed battery is an electrical installation, so follow the installer and manufacturer guidance.
If you already have solar panels, adding a battery is one of the most common upgrades. The first technical question you will meet is whether the battery is AC-coupled or DC-coupled. The names describe where the battery joins your system.
The difference in one picture
Solar panels make direct current (DC). Your home runs on alternating current (AC). An inverter or microinverter converts one to the other.
With DC coupling, the battery is connected to the panels' DC side. Power can flow from the panels into the battery without being converted to AC first, and a single hybrid inverter often does the conversion for both. With AC coupling, the battery has its own conversion equipment and connects on the AC side, after your existing inverter. Your panels and inverter carry on working as they were.
Side by side
| DC-coupled | AC-coupled | |
| Where it connects | Panel side, before the inverter | Mains side, after the inverter |
| Conversion steps | Fewer for stored solar power | More, so some energy is lost |
| Fit for existing panels and inverter | Often needs the inverter replaced or changed | Usually leaves the existing equipment in place |
| Charging from the grid | Depends on the product | Usually straightforward |
Which suits panels you already have
If you already own panels with a string inverter or microinverters, AC coupling is often the simpler route, because it works alongside what you have. If you are replacing the inverter anyway, a DC-coupled hybrid system may be worth a look. The right answer depends on your inverter's make and age, whether it is a string inverter or microinverters, and the battery's voltage and limits.
For reference, Wrenstead Store 1, Store 2 and the H1600 Smart Solar Hub are DC-coupled. They charge and discharge the battery on the DC side and pass that power to a microinverter, which produces the AC that feeds your home. They are not add-on batteries that connect to the AC side of a system you already have. So whether one of ours suits you depends on how your panels and inverter are arranged today. If you are not sure, send us your inverter and panel details before you order.
Our guide to battery storage for existing solar panels explains how this applies to Wrenstead Store 1 and Store 2, and the compatibility page lists what we need to know about your setup.
What to check before you buy
- The make and model of your existing inverter or microinverter, and the panels' ratings.
- Whether the battery's limits for voltage, current and power match your equipment.
- Whether you want to charge from the grid on a cheap overnight tariff. See scheduled off-peak charging.
- Where the battery will live. Cold affects charging, as we explain in our guide to solar batteries in a UK winter.
- How much you would realistically use from it each day. A 1.024kWh battery shifts at most about 1kWh a day, and a 2.048kWh battery about 2kWh.
Having solar panels does not mean an existing system will work with any battery. Check compatibility before ordering. If you are unsure, send us your inverter and panel details through the contact page.
Installation and notification
A fixed battery connected to your home wiring is an electrical installation. The wiring should be done by a qualified electrician, and the connection may need to be notified to your network operator. Ask your installer what applies to your system, and read our installation and connection guide. This is different from plug-in solar, which uses a standard socket and excludes batteries.
General explanation of AC and DC coupling. Details of what applies to your equipment must come from your installer and the product's manufacturer instructions. By the Wrenstead Energy team.